Technical-Resources

/

Technical Resources

CEA-Referenced Documentation

Bird Flight Diverter
Specifications& Documentation

Consolidated technical specifications, CEA spacing guidelines, installation procedure, type-test documentation and downloadable datasheets for the complete Prakritis bird flight diverter range — Aero Spin, LED and Non-LED.

3
Model Datasheets
CEA
Guideline Referenced
3
Made In India
7+
Type Tests Per Model

Technical Specifications

Bird Flight Diverter
Specifications, Compared

The full engineering specification for Aero Spin, LED and Non-LED bird flight diverters, side by side. Every parameter below is verified as part of Prakritis’ type-test programme — see Testing & Quality Assurancefor methodology.

Technical specification comparison for LED and Non-LED bird flight diverter models
Specification Parameter LED Blinking Marker
(PLM / LD-V1)
Non-LED Marker
(PLM / NLD-V1)
Power Requirement Solar (Self-contained, no grid needed) None — Fully passive
Maintenance Requirement Minimal — Sealed electronics Zero — No electronics or moving parts
Weight Less than 500g Less than 350g
Daytime Visibility Retroreflective + Active LED Retroreflective surface
Night Visibility High-intensity LED blinking (1km+ range) Photoluminescent glow-in-dark
Conductor Clamp Size Universal — 5mm to 38mm Universal — 5mm to 38mm
Working Temperature −20°C to 100°C −20°C to 100°C
CEA Compliance Fully compliant Fully compliant

For model-specific installation guidance, applications and downloadable datasheets, visit the Aero Spin, LEDor Non-LEDproduct pages directly.

Installation Guide

Live-Line Installation,
Standard Across the Range

Every model in the Prakritis range shares the same universal clamp and is designed for hot-stick installation on energised conductors, avoiding the need for a planned line outage. The general sequence below applies to all three models; model-specific notes (such as solar panel orientation for the LED unit) are covered on each product page.

Spacing & Site Assessment

Confirm mounting points against the site’s diverter spacing plan — see CEA Guidelines below — and record conductor or earth wire diameter at each point.

Crew & Procedure Readiness

Installation is carried out by trained live-line crews using standard hot-stick procedure and the utility’s approved live-line work method statement.

Clamp Engagement

Position and close the universal clamp on the energised conductor. The clamp accommodates 5mm–38mm diameters without adapters or model changes.

Model-Specific Checks

LED units require solar panel orientation toward maximum daily sun exposure; Aero Spin and Non-LED units require a free-rotation check for the flapper assembly.

Verification & Sign-Off

Confirm clamp security against the rated pull strength (>100kg) before withdrawing the hot stick, and log the installation point against the site diverter register.

Regulatory Reference

CEA Guidelines for
Bird Flight Diverters

Indicative bird flight diverter spacing by transmission line voltage class, referenced against CEA guidance
Voltage Class Recommended Diverter Interval Staggered Placement Primary Application Note
33 kV – 66 kV 10 m – 15 m Yes Distribution & Sub-transmission lines near flight corridors
132 kV – 220 kV 10 m – 12 m Yes Central phase and shield wires in high-density bird zones
400 kV 5 m – 10 m Yes Earth wire / OPGW and top conductor lines (CEA priority)
765 kV & Above 5 m Yes High-altitude & GIB (Great Indian Bustard) habitat corridors

What the CEA Specification Covers

Mechanical Requirements

Clamp pull strength, UV and weathering resistance, and dimensional tolerances for the diverter body and flapper assembly.

Electrical Clearance

Minimum clearance and dielectric requirements to ensure the diverter does not compromise line insulation or induce corona discharge.

Visibility Performance

Minimum reflective area, photometric output for active devices, and colour contrast requirements against typical sky and terrain backgrounds.

Spacing Guidance

Indicative diverter spacing by voltage class, tightened at identified high-risk zones such as Great Indian Bustard habitat corridors.

The figures above are indicative and intended for initial planning. Final spacing should always be confirmed against the current CEA advisory in force and a site-specific risk assessment — our engineering team can assist with corridor-specific spacing plans.

Testing & Quality Assurance

Verified Before
It Ever Reaches a Line

Every model in the range is subjected to the same core type-test programme before dispatch, in line with the CEA technical specification for bird flight diverters.

UV & Weathering

Accelerated UV exposure and thermal cycling to verify housing and reflective materials retain performance across the full 15-year design life.

Mechanical & Pull Strength

Clamp pull-force testing beyond 100kg and vibration testing to simulate wind-induced conductor motion over the operational life of the device.

Electrical Clearance

Dielectric and clearance verification confirming the diverter does not compromise line insulation or induce corona discharge on energised conductors.

Photometric Output

Reflective intensity and, for the LED model, luminous output and blink-pattern verification against the minimum visibility thresholds referenced in the CEA specification.

Ingress Protection

IP65 sealing verification for the LED model’s solar panel and battery housing, confirming resistance to dust ingress and low-pressure water jets.

Batch Consistency

Dimensional and material sampling across every production batch to confirm consistency with the type-tested reference unit before dispatch.

Downloads

Datasheets &
Catalogues

Everything a procurement or specification team needs in one place — model-wise datasheets, the full range catalogue, installation guide and compliance documentation.

Model Datasheets

Aero Spin — AEROSPIN-V1

Dimensional drawings, materials and mechanical ratings for the Aero Spin diverter.

Download PDF
LED — PLM/LD-V1

Electrical parameters, runtime data and dimensional drawings for the LED diverter.

Download PDF
Non-LED — PLM/NLD-V1

Material specifications and dimensional drawings for the Non-LED diverter.

Download PDF

Catalogues & Guides

Full Product Catalogue

Aero Spin, LED and Non-LED models in one document, with application guidance.

Download PDF
Installation Guide

Full hot-stick installation procedure with model-specific notes and diagrams.

Jump to Guide
CEA Compliance & Approvals

CEA specification reference documentation.

View Approvals

Research & Field Data

Design Choices,
Grounded in Field Behaviour

The three-model structure of the Prakritis range — and the specific mix of retroreflection, photoluminescence and active illumination used within it — is informed by published avian ecology literature on bird flight behaviour and collision risk, alongside field observation from installed corridors and consultation with utility engineering teams on real-world maintenance constraints.

We do not publish proprietary field data on this page, but our engineering team can share methodology summaries, monitoring approach, and relevant third-party research references on request — particularly useful for environmental clearance submissions and academic or NGO collaboration around Great Indian Bustardand wetland bird corridor protection.

Field Installation Feedback

Installation and maintenance data gathered from utility partners informs iterative refinement of clamp design and housing durability.

Avian Ecology Literature

Visibility mechanism selection draws on published research into large-bird flight mechanics, reaction distance and low-light collision risk.

Environmental Clearance Support

Documentation and methodology summaries are available to support EIA and environmental clearance submissions for renewable and transmission projects.

Common Questions

Documentation,
Answered

Questions we hear most often from procurement, EPC and design engineering teams reviewing this page.

What spacing does CEA recommend for bird flight diverters?

Recommended spacing varies by voltage class and species risk, generally tightening on higher-voltage, wider-conductor-bundle lines. Indicative spacing by voltage class is provided in the CEA Guidelines section above; final spacing should always be confirmed against the current CEA advisory and a site-specific risk assessment.

What type tests are performed on Prakritis bird flight diverters?>

Every model undergoes UV and weathering resistance testing, mechanical pull and vibration testing, dielectric clearance verification, and photometric testing of reflective or LED output, in line with the CEA technical specification for bird flight diverters. See Testing & Quality Assurance above for the full list.

Where can I download datasheets and the product catalogue?>

Model-wise datasheets, the full product catalogue and installation guide are available for download in the Datasheets & Catalogues section on this page, or by contacting our engineering team directly for a procurement-ready document package.

Do you provide spacing plans for a specific project? >

Yes. Our engineering team can review your line voltage, span length and corridor risk profile to recommend a spacing and model-mix plan aligned with CEA guidance and your project’s environmental clearance conditions.

Get in Touch

Need a Document We
Haven’t Listed Here?

Type-test certificates, approval letters, EIA-support documentation or a corridor-specific spacing plan — our engineering team can put together the exact package your submission needs.

Scroll to Top